Test equipment · Product range

From lab bench to megawatt centers. Delivered turnkey.

All test means are designed, built and factory-tested by EXOES in Bordeaux (FR), then installed and commissioned on your site, worldwide.

One range, from kilowatts to megawatts

POWER · LOG SCALE

20

years of expertise

100+

industrial customers

100%

on-time delivery

100%

SAT passed first time

The range

Three scales. One turnkey approach.

Whatever the size of your test facility, the same team designs, builds, tests and commissions it. Pick the scale that matches your validation needs.

Lab-scale test setup with three TTV cabinets, a power rack and an HMI
01 · LAB30 kW

Lab-scale test setup

Cold plates, thermal interface materials, components (QDs, pipes…) and fluids, on regulated and instrumented loops.

See the lab range
Modular rack emulator
02 · RACK22–400 kW

Modular rack emulator

Rack CDUs, liquid-cooling loops, in-rack components and power equipment, tested on the same hardware as a real data center.

See the rack range
Containerized test center with outdoor tanks and cooling units
03 · TEST CENTER1–10 MW

In-building or modular test center

MW-scale CDUs, cooling infrastructure and power equipment, delivered in containers and commissioned on your site.

See the test center
Lab-scale test setup

01 · Lab · 30 kW

Lab-scale test setup

Characterize cold plates, thermal interface materials, components and fluids on a lab bench, with thermal test vehicles (TTV) that reproduce the heat load of your chips.

What you can test

Cold platesThermal Interface MaterialsComponents (QDs, pipes…)Fluids
  • Multiple single and multi-zone TTVs, up to 10 kW each
  • Dedicated chiller and instrumented loop per TTV
  • Regulated power zones, custom HMI
Total power
30 kW
Power per TTV
up to 10 kW
Modular rack emulator with a liquid-cooled server tray pulled out

02 · Rack · 22 to 400 kW

Modular rack emulator

Emulate a liquid-cooled rack without a single chip. Validate your CDUs, loops and in-rack components under realistic load, on the same hardware as a real data center.

What you can test

Rack CDUsLiquid-cooling loopsIn-rack componentsPower equipment
  • From a single 22 kW blade to a full rack
  • Same hardware as in a real data center
  • Silicon-free, rack-scale emulation
Power
22 to 400 kW
Configurations
Single blade to full rack
Containerized test center

03 · Test center · 1 to 10 MW

In-building or modular test center

Power, cooling and test cells in containers: a MW-scale validation facility that installs outdoors and scales module by module.

What you can test

MW-scale CDUsCooling infrastructurePower equipment
  • Power, cooling and test cells in containers
  • Outdoor installation, scalable by module
  • Delivered and commissioned on your site
Power
1 to 10 MW
Format
Containerized, modular

Test equipment · Design & integration

One partner. One integrated approach.

Custom-engineered and turnkey test solutions, delivered end-to-end. From engineering studies to turnkey delivery, EXOES provides a single point of responsibility for your test equipment.

01 · EQUIPMENT

Turnkey equipment

  • Fixed scope, single point of responsibility
  • FAT in Bordeaux (FR), SAT on your site
  • Operator training at handover

02 · ENGINEERING

Custom engineering

  • Requirements definition and safety studies
  • System sizing and custom architecture
  • Software: HMI, PLC

03 · SUPPORT

Maintenance & support

  • Preventive and corrective maintenance
  • Remote and on-site support
  • Validation support

ENGINEERING DNAPower & electrical

ENGINEERING DNAThermal management

ENGINEERING DNAFluid & hydraulic

ENGINEERING DNASafety & risk

How it works

From your requirements to a commissioned test facility.

  1. 01

    Define

    We capture your requirements and run the safety studies.

  2. 02

    Design

    System sizing, custom architecture, and the HMI and PLC software.

  3. 03

    Build and FAT

    Built and factory-tested in Bordeaux before anything ships.

    BORDEAUX, FR
  4. 04

    Install and SAT

    Installed and commissioned on your site, with operator training at handover.

    YOUR SITE, WORLDWIDE

FAQ

Questions we often hear.

Something else in mind? Ask us directly

Where are the test means built?

All test means are designed, built and factory-tested by EXOES in Bordeaux (FR), then installed and commissioned on your site, worldwide.

Can a setup be adapted to our needs?

Yes. Custom engineering covers requirements definition, system sizing, custom architecture and software (HMI, PLC), so the setup matches your test plan.

Is operator training included?

Yes, operator training is part of the turnkey delivery, at handover.

What happens after delivery?

EXOES provides preventive and corrective maintenance, remote and on-site support, and validation support.

Let's talk

Equip your test lab.

Tell us what you need to validate and at what scale. We come back with a turnkey proposal.

Headquarters

EXOES, 6 Avenue de la Grande Lande
33170 Gradignan, France
Scale of interest

EXOES uses the information you submit only to answer your request. See our privacy policy.